- Overview
-
WarmWire cables are very close to SunTouch mats in construction and provide the same cozy heat for your floors, but cost less and install differently.
To install WarmWire you need to:
- Place and attach the WarmWire strap to the subfloor;
- Weave the wire back and forth between straps to create your own heated area (while doing that space the wires depending on your warming needs.)
- Cover with thin-set or self-leveling mortar. You can then use almost any floor covering with WarmWire (tile, stone, wood, laminate, carpet)
Why WarmWire is so Great?
- Easy to install in rooms of any size or shape;
- Safe good for installation in showers;
- Ultra-low EMF with Active Shielding & Twin-wire technology;
- Durable 3-layer protection with a 25 year warranty
- Flexible easy installation for curves and angles
- Available in 120VAC and 240VAC
- Armored 3-wire power lead - no return wire from the end 1 Connection
- Long life with oxygen-free copper heating elements
- High Performance ETFE insulation
- Protected by woven stainless steel braid
- Strengthened with polyurethane outer jacket for ultimate impact & cut resistance
- Safe grounded from end to end and UL listed in USA & Canada
If you have any questions or need help selecting the right WarmWire cable length for your project feel free to call us at (866) 558 3369 or email us atsales@warmyourfloor.com. We will be happy to help you get exactly what you need!
- Product Details
WarmWire = Zero EMF
An emerging issue in the electric radiant heat industry is EMF (electromagnetic field) radiation. SunTouch pioneered and sells only ZERO EMF products constructed with active dual wire EMF-canceling technology.
All SunTouch products use a complex wire construction with two heating elements in parallel with an added and patented helical twist to eliminate EMF. Other electric radiant floor heating companies sell single-wire systems that release high levels of EMF when compared to SunTouch.
What is EMF? Electromagnetic fields (EMF) come from all electrical appliances, but studies show an average American's daily exposure is less than 1 unit (mG) of EMF. But. when you sit on an unshielded electric radiant floor, you may be exposed to 20, 40, or more times the average daily exposure. This Data comes from Independent testing. Read More Here
Is limiting exposure to EMF important? No one is certain. The World Health Organization says the data is inconclusive to date, but continues their research. We provide this EMF information because it is important to some people, not to frighten you or exaggerate any risk.
For many years customers have chosen SunTouch Zero EMF systems, but we leave the choice to you after explaining what we do know.
What's In The Box WarmWire Spool in Easy to dispense box. Detailed Installation Manual. DVD on request Warranty from Manufacturer 25 year warranty backed by USA Manufacturer since 1873 Heated Area Size Covered 200.00 Amp Draw 10.00 Cable length in inches 11280" in. inch Cable length in feet 940' ft. feet Cable length in meters 284.85 m meter metre Heated Area 161+ Square Feet Wattage : Total watts 2400 watts Installation Style Heating Cable secured to floor using Metal Cable Strap (track). Strap secured to floor with tape,screws or glue Custom Size Options None. Standard lengths only. No customization Safety Listing UL (Underwriters Laboratory) Listed for U.S. and Canada under UL 1673 and CAN/CSA C22.2 No. 130-03, File No. E185866 Color Clear flexible Polyurethane Coating Jacket over Stainless Steel braid Cable strap or guides 5 recommended (1 for every 40 - 50 sq ft) Acceptable Floor Coverings Natural Stone,Tile, Laminate, Engineered Woods, Carpet, Vinyl, Linoleum, Solid Hardwood (if you use sleepers) Made In USA Made in USA - How to Install


Step 1:
Plan your layout and determine the cable direction. Measure
about 3" in. inches from the wall, and place strap parallel to
the wall. Under toe kick spaces, install the strap 1.5"in. inches
to 2" in. inches away from the vanity.
Step 2:
Cut the strap to length for each side of area
to be heated.


Step 3:
Secure the strap to the subfloor using double-sided
tape, glue, or fasteners.
Step 4:
Fill in each section back and forth with cable,
spacing the wire 2.5" or 3" in. inches
apart. For additional areas, cut and attach the
straps accordingly and begin weaving the
wire into that area.

Important:
If cables are running greater than 3' or 4'ft. feet across a room, be sure to add another
strap to thread through in the center of the area to be heated.
WarmWire Installation Video Instruction Manual WarmWire 240200WD 200 Sq Ft 240V Radiant Floor Heating Cable Installation Manual Skill Level : D-I-Y Simple for Install, PRO for Electric Running Cable more difficult + more time than MATS. Installation only by qualified persons. Electrician recommended for wiring. Read More GFEP / GFCI Protection Required (Ground Fault Circuit Interrupter) Required for each circuit - INCLUDED in SunStat Control Circuit Breakers and Supply Wire (always follow local code) Mats or Wire Supply Wire Breaker VAC total amps (AWG*) qty type rating 120 up to 12 amps 14 1 single pole 15 or 20 A 120 up to 15 amps 12 1 single pole 20 A 240 up to 12 amps 14 1 double pole 15 or 20 A 240 up to 15 amps 12 1 double pole 20 A * Recommended only. Follow local codes for wire gauge size.
Maximum Circuit Load 15 Amps Maximum Circuit Overload Protection 20 A Breaker. Electrical Box Size (Where Mats connect to Thermostat) Extra-deep single-gang box for 1 or 2 leads, Or 4" square deep box for 3 cables (extra room needed for Wire, wire nuts, control) Full Length End-to-End ground wire Yes. Heating Wire construction ETFE Fluoropolymer, Stainless Steel Ground Braid shield and Outside layer of Clear Polyurethane Heating Elements (Dual Wire) Oxygen-free copper or nickel-copper Repairable Heating Wire Yes, Wire can be repaired. Repair kits and assistance available. Shower Installation Permitted Yes, can be installed in a tiled shower. UL listed, verify local code. Installation Layout Map customized for my project No - example in manual. We provide Layout Maps only for MATS Expected Floor Temperature Dependent on Many factors, insulation recommended. Insulation Recommended Yes; under slabs or framed floors. Cork or similar on top of Concrete Subfloor as thermal break Indoor Installation Only INTERIOR floor heating application only. Embedded in mortar or self leveler only Installation On Sub Floor on TOP of Sub Floor (Plywood, backer board, concrete) Distance from Wax Ring at toilet flange install 4 - 6 inches away; can be under front of toilet. Approx 20" from wall Trowel Size recommended Minimum 3/8" x 1/4". Dependent on tile size - verify with tile/mortar manufacturer Trowel type Recommended Heavy Duty Plastic PRO-Trowel Cut Warning Never cut the heating elements to shorten Minimum Installation Temperature 50° Degrees F / 10° Degrees C - Specifications
Voltage 240 VAC How to choose 120 or 240 Volt Same Energy efficiency & same Watts/SF. More Sq Footage per circuit with 240v Watts Per SF 12 Watts per Sq Foot @ 2.5" in. inch spacing Heat Output BTUs per SF 41 BTU per Sq Ft/Hour @ 2.5" in. inch spacing Heating Power : Total BTU's 8200 BTU total Manufacturer Watts Radiant Brand Name SunTouch Warm Wire Power Lead Type Armored, NEC color code, Single point connection at 1 corner of mat. No return wire like inferior products Power Lead Length 10 Feet Power Lead Wire Gauge (varies by heated area) 14 AWG Packaging Easy Open Cardboard - no frustration. Easy to dispense wire from box Product Thickness 1/8" - 3/16" (nominal) Shorter cables are thinner. Heating Wire Spacing 2" - 2.5" - 3" on center Minimum Bend Radius 1/2" 0.50 inch Weight 20.95 Ohms Reading (resistance value) 20-26 ohms ZERO* EMF (Electro Magnetic Field) Yes. Verified by Independent Testing Laboratory as ultra low. Controls/Thermostat is required for operation SunStat Floor sensing thermostat Conduit required for Power Leads Conduit is not required for Power Leads Width of heating area Feet Variable - you determine layout width, length, shape Spacing between runs (inches) Heated SF Watts Per SF BTUs/SF/Hr 2 160 15 51 2.5 200 12 41 3 240 10 34 - Reviews